9000 & 12000 BTU Wiring (Sharkaire)

9000 & 12000 BTU Wiring (Sharkaire)

Sharkaire 12000 BTU units configured to work under 110 VAC and 12 Amp electrical service. The entire units power through indoor unit via provided white power plug no other power sources is required.

Wiring terminals in both indoor and out door units are clearly marked.  

 

 

 In some cases cable colors are different and not matching with the supplied wiring diagram. 

Please refer the two sample wiring pictures below!!

Brown goes   terninal "1" 

Purple /Red goes      terminal "2" 

Light orange/ Yellow goes  terminal "3"  

Blue goes    terminal "N"

Green goes   terminal "Ground"